馃攳
Power Saver Scam EXPOSED! - YouTube
Channel: ElectroBOOM
[0]
Hi, and happy new year!
[1]
Hehe
[2]
*Reps god-tier merch*
[3]
A lot of people ask me to check these "power saver" devices that are supposed to save you tons of
[8]
money by reducing power usage at home.
[11]
What these things claim to do is a power factor correction when plugged in,
[15]
and if you search about them, you'll see tons of videos talking about what a piece of garbage these are!
[20]
But WAIT until you hear my opinion about it!
[22]
That is, if YouTube is not blocked in your country.
[25]
That's why this video is sponsored by ExpressVPN!
[28]
Not only it greatly secures your internet experience against all sorts of threats [they're in the air it seems]
[33]
It allows you to access websites and contents that are blocked in your country.
[37]
Actually, I traveled to China back in March, 2018, and I was cut off from my YouTube and social media.
[43]
Coincidentally, I installed ExpressVPN on my phone and laptop, turned it on, and BAM!
[48]
I LOOPED around the filters imposed by the government of people!
[52]
*Russian national anthem plays*
[52]
*Russian anthem stops* BUT WAIT!
[53]
Follow this link; get three months free on a one-year package for less than seven dollars a month,
[58]
and afterwards, if you still feel like letting your identity get stolen.
[62]
Anyway, I bought my own "power saver" from Amazon.
[66]
This one says, "INTELLIGENT ENERGY SAVER; THE RESULT IS THE BEST."
[70]
So there must be some smarts in it.
[72]
Let's cut it open!
[73]
*Slow, intense, appropriate, piano music plays*
[76]
*Music stops* Well, there is an LED and some resistors in here to indicate that you have plugged it in,
[81]
in case you're deaf and can't see that you have plugged this GIANT brick into the wall.
[86]
[I CAN'T HEAR IT'S TOO DARK IN HERE]
[86]
And then, there is this potted, black box that...I suppose the brains are in here.
[92]
Let's cut it open!
[92]
*Cue same montage piano music from before*
[96]
*Music stops* THE F*CK?!
[97]
This black box is a single component, a high voltage capacitor,
[100]
with a value of
[102]
around
[103]
2.1 Microfarad
[105]
There is no "brain" in this sh*t!
[107]
They lied!
[108]
All of them lied! Those f*cking son of a...
[110]
*Cutting himself off, sighing* Okay, wait.
[111]
So, this is the same garbage as all of them.
[113]
Just a capacitor placed directly on the power lines.
[116]
But, capacitors are, in fact, used to improve power factor.
[119]
See, as I explained before, there are two types of AC power.
[123]
One of them is 'real' or 'active' power, where the load comsumes the power and does the work,
[128]
and the voltage and current are in phase.
[130]
It is like walking:
[131]
the force you apply that moves you forward does the work for you.
[135]
The other type is reactive power that is due to capacitive or inductive loads and doesn't do any work at home
[141]
because the net 'active' power draw by these components is zero.
[145]
And depending on if the load is more inductive or capacitive
[149]
The current lags or leads the voltage by 90 degrees
[152]
Like when you walk, you have to lift your leg and body up and down.
[156]
That force doesn't move you forward but results in inefficiency and waste of power at the source.
[161]
And the combination of active and reactive power is called "apparent power".
[166]
And the power factor is just the active power divided by apparent power.
[170]
We want the power factor to be 1, so that all the power transmitted is used.
[175]
The downside of the reactive power is that
[177]
although it doesn't do any work, it results in current flow through the power line, increasing the power losses.
[183]
It is significantly higher in factories and industries
[186]
that use tons of AC motors and transformers
[190]
That's why most reactive loads are inductive
[192]
with current lagging behind the voltage.
[195]
And we know that in capacitors the current is leading the voltage
[198]
So if we add a capacitor parallel to the inductive load
[202]
With the peak current equal to the inductor current 180 degree out of phase
[209]
They add up and cancel each other
[211]
Power factor fixed!
[212]
For example, most fans with AC motors
[215]
don't have a capacitor in them to correct the power factor
[219]
It is drawing 0.7 Amps and i have a 10 microfarad capacitor
[224]
Watch the current carefully as i connect the capac-
[226]
*OOF* F*CK!
[228]
*Oh Mehdi*
[230]
The capacitors used on powerline are rated for high voltage and are not polarized
[234]
Anyway at home the reactive power is not doing anything for me
[237]
I shouldn't have to pay for it
[239]
In fact, lemme check with BC Hydro or local power supplier
[243]
*CALL WAITING MUSIC*
[245]
*trying to be sexy voice* Uh i have a question about my
[247]
Power factor
[248]
*Female voice over the phone*: Cutting out i can't hear you hello?
[249]
Depending on the power factor you charge differently
[253]
Is that for business customers only?